Sign In | Join Free | My burrillandco.com
Home > Fin Tube >

ASTM SA210 Gr A1 Carbon Steel Longitudinal Fin Tube for Heat Exchangers

    Buy cheap ASTM SA210 Gr A1 Carbon Steel Longitudinal Fin Tube for Heat Exchangers from wholesalers
     
    Buy cheap ASTM SA210 Gr A1 Carbon Steel Longitudinal Fin Tube for Heat Exchangers from wholesalers
    • Buy cheap ASTM SA210 Gr A1 Carbon Steel Longitudinal Fin Tube for Heat Exchangers from wholesalers
    • Buy cheap ASTM SA210 Gr A1 Carbon Steel Longitudinal Fin Tube for Heat Exchangers from wholesalers
    • Buy cheap ASTM SA210 Gr A1 Carbon Steel Longitudinal Fin Tube for Heat Exchangers from wholesalers
    • Buy cheap ASTM SA210 Gr A1 Carbon Steel Longitudinal Fin Tube for Heat Exchangers from wholesalers

    ASTM SA210 Gr A1 Carbon Steel Longitudinal Fin Tube for Heat Exchangers

    Ask Lasest Price
    Brand Name : YUHONG
    Model Number : Longitudinal Fin Tube
    Certification : ABS, GL, DNV, NK, PED, AD2000, GOST9941-81, CCS, ISO 9001-2008
    Price : Discussion
    Payment Terms : T/T, L/C at sight
    Supply Ability : according to client requirements
    Delivery Time : 15-30DAYS
    • Product Details
    • Company Profile

    ASTM SA210 Gr A1 Carbon Steel Longitudinal Fin Tube for Heat Exchangers

    ASTM SA210 Gr A1 Longitudinal Fin Tube With Carbon Steel Fin


    Longitudinal finned tube is a kind of high-efficiency heat transfer element, which is made by closely welding or integrally forming metal thin fins along the axial direction on the outer surface of metal base tube (such as steel, copper, aluminum). Its core value lies in expanding the heat transfer area outside the tube by several times to dozens of times (the fin ratio can reach 5~20 times).


    This structural design specifically solves the efficiency bottleneck problem of heat exchange between gas (such as air, flue gas) and fluid in the tube (water, steam, refrigerant, etc.). Due to the extremely low heat transfer coefficient on the gas side, it often becomes the dominant factor in the thermal resistance of the system; the fin penetrates the gas boundary layer deeply by extending the heat transfer surface, and uses the disturbance effect of the fin edge on the airflow to significantly reduce the thermal resistance on the gas side, so that the overall heat transfer efficiency can be increased by 2~10 times compared with the bare tube.


    Reliable manufacturing is the key to achieving its performance, which mainly relies on processes such as high-frequency resistance welding, integral extrusion (such as aluminum tube) or brazing. These processes ensure that the connection interface between the fin and the base tube has high thermal conductivity (reducing contact thermal resistance) and sufficient mechanical strength to withstand thermal stress and vibration under working conditions.


    When designing longitudinal finned tubes, it is necessary to finely optimize the fin parameters (height, thickness, spacing) to strike a balance between maximizing heat transfer performance and controlling gas flow resistance (pressure drop). At the same time, it is necessary to take into account both material selection and special working conditions, such as selecting corrosion-resistant materials (such as ND steel or coating) in environments prone to dew point corrosion such as sulfur-containing flue gas, considering anti-ashing resistance in dusty gases (such as using larger fin spacing), and ensuring structural reliability under vibration conditions.


    Based on its excellent gas-side heat transfer enhancement and compactness, longitudinal finned tubes are widely used in various scenarios dominated by gas-liquid heat exchange and with high space or efficiency requirements. Typical applications include: waste heat recovery equipment (economizer, air preheater) in boiler systems, process gas coolers/heaters in the petrochemical industry, evaporators/condensers in refrigeration systems, and hot air heaters in industrial drying equipment. It is a key technology to achieve compact equipment and efficient energy utilization.


    Relationship between fin direction and airflow

    TYPEFin directionAirflow directionConvection mechanism
    Longitudinal Fin TubesFins are parallel to the tube axisGas flows parallel to the finsAirflow flows along the length of the fins, with weak disturbance
    Horizontal fin tubeFins are perpendicular to the tube axis (spiral/annular)Gas flows perpendicular to the finsAirflow is forced to rotate/disturbed by the fins, causing strong disturbance



    Heat transfer performance and resistance comparison


    CharacteristicsLongitudinal fin tubeHorizontal fin tube
    Heat transfer coefficientMedium (weak air flow disturbance)Higher (swirl destroys boundary layer)
    Heat transfer areaFin ratio 5~20 timesFin ratio 10~30 times (can be higher)
    Air flow resistanceLower (straight flow channel)Significantly higher (swirl energy consumption)
    Anti-dust accumulationExcellent (straight channel is not easy to be blocked by dust)Poor (spiral groove is easy to be blocked by dust)

    Application

    Energy and power


    Boiler economizer, air preheater, gas turbine waste heat boiler


    Petrochemical


    Process gas heater/cooler, reaction product condenser, lubricating oil coolin


    HVAC & refrigeration


    Evaporative condenser, air cooler coil, heat pump outdoor unit


    Industrial waste heat recovery


    Drying equipment, ceramic kiln, glass melting furnace flue gas waste heat utilization


    Transportation machinery


    Diesel engine intercooler, hydraulic oil radiator



    Quality ASTM SA210 Gr A1 Carbon Steel Longitudinal Fin Tube for Heat Exchangers for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yuhong Group Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)